Thursday, June 23, 2011

Pre-wiring for a telephone system



Pre-wiring your system:
 
 
Wiring taken:

The plots for each of the eight plots taken at the facility are connected by the cable 8 son.

Extending your installation .
Who can install additional outlets?

  • The technical services of France Telecom.
  • A company of your choice.
  • Yourself, from an existing phone jack.

If your installation has at least one outlet, it is possible to change in order to add additional outlets.

If your phone is connected to a rose, you will need for the installation of catch, using the services of France Telecom technical or business qualified phone.

Precautions:

It is recommended prior to any intervention to isolate your installation by disconnecting the two son of the first row of the connector (pins 1 and 3) avoiding they touch. You just put them back in the late work.
Warning:
As an electrical installation, it is dangerous to change your telephone during a storm.

Recognize your installation:
It may be that your installation was carried out according to old standards. The different types of installation you can change are given in the table below.



R EPRESENTATION diagram of the existing facility. Block diagram of the system after adding an additional outlet. Equipment to be used (see "Materials"). Observations (see "Wiring").


tel16
First dose to 6 blocks.


tel17
6 studs 8 studs

- 1 to 8 pin socket - a test module - 4 pair cable

Installing new standard if you plan to completely redo your installation, it shall conform to the wiring to the above case.
tel16
First dose to 8 blocks.
tel17
8 blocks 8 blocks
- 1 8-pin socket - 4 pair cable


tel19
First taken in 8-pin & ring.


tel18
6 studs 8 studs 8 studs
tel22
- 2 pin plug to 8 - a test module - 4 pair cable - flexible cord 2 pair - one phone jack - a 2.2 uF capacitor




Taken within a six blocks. Within an 8-pin socket.


Wiring phone jacks:
 
TYPE 1:
from a 6-pin socket.
If the plug is fitted with a wire or a strap (wire) between pins 1 and 5, or a capacitor, it must be removed.
 
TYPE 2:

from an existing 8-pin socket.  

TYPE 3:

taken from a 6-pin associated with an extra bell. If the plug is fitted with a wire or a strap (wire) between pins 1 and 5, or a capacitor, it must be removed. It should be taken to conform with the existing wiring diagram-cons.

wiring of the alarm:
Use with a second line.
 

Was the pattern of pre-wiring telephone jacks.